airCore 700

airCore 700 Ducted Split AC

airCore 700_header

airCore 700

airCore 700 Ducted Split AC

The airCore700 stands as Hitachi’s flagship residential ducted split system range. It delivers outstanding cooling and heating performance, showcasing a wide capacity range and efficient operation in diverse ambient temperatures, while guaranteeing uncompromised comfort. Utilising R32 refrigerant, airCore700 units have a lower global warming potential compared to R410A refrigerant products.
airCore 700_0

Peace of Mind with a 6 Year Warranty

The airCore700 ducted split range comes with a comprehensive 6 Year Warranty on parts and labour, so you can be assured of the reliability and quality of your airCore700 system.

airCore 700_1

Extreme Temperature Operation

Designed for the harshest conditions, Hitachi airCore700 units are designed to operate in ambient temperatures from -15°C to 52°C to ensure you’re always comfortable, whatever the weather.

airCore 700_2

Frostwash Self-Cleaning Technology

All indoor ducted units are equipped with FrostWash. FrostWash freezes the dirt and dust trapped in the indoor unit heat exchanger, which is drained away with the condensate when it defrosts – effectively cleaning the heat exchanger and helping to safeguard long-term performance by maintaining good airflow. FrostWash can be activated manually or automatically at scheduled intervals.

airCore 700_3

R32 low GWP Refrigerant

Reducing environmental impact, airCore700 systems use R32 refrigerant which has a lower global warming potential (GWP) than traditional R410A refrigerant.

airCore 700_4

Ducted Indoor Units

airCore 700 offers mid-static (standard homes) and high-static (large homes) pressure ducted systems, suitable for various layouts and applications. The mid-static (standard home) pressure range is 35-215Pa, while the high-static(large homes) pressure range is 35-310Pa. The high-static ducted indoor units feature an easily splitable design, allowing effortless removal and reassembly of the fan cover from the heat exchanger compartment using a simple 'one-click' mechanism. This disassembled design is perfect for installations in tight spaces like rooftop attics and narrow areas, simplifying delivery and installation for greater convenience.

Advanced Control

The power is in your hands with our award-winning airPoint Room 700 controller option. With simple navigation and feature rich functions and settings, offering advanced control with your airCore700 ducted system.

Backlit Colour Controller

airCore 700_5

Display Adjustment options

The colour screen visual interface allows you to adjust the brightness of the backlight, dim or turn off backlight after inactivity and set screen theme to light or dark.

Energy Usage Monitoring

airCore 700_5

Power Consumption Display

Power consumption displays the power consumption of the outdoor unit compressor. The value of each displayed in Graph/List format is 1 day (every 2 hrs.), 1 week (7 days), and 1 year (12 months).

Operation Schedule Setting

airCore 700_5

7 Day Operating Scheduling

Operation schedule function is a 7-day timer used to automatically start or stop the unit operation at the set time. The temperature can also be set. Up to 5 schedules can be set for each day of the week including scheduling for a holiday, six days in advance.

Power Saving Setting

Power Saving Setting

Power Savings setting helps reduce energy consumption with low, medium or high settings available.

Night Quiet Operation

Night Quiet Operation

Night Quiet Operation significantly reduces the noise levels of the outdoor unit and offers the feature to schedule Night Quiet Operation for indoor units.

AutoBoost Setting

AutoBoost Setting

AutoBoost function provides powerful cooling and heating for 30 minutes once the operation starts to rapidly cool or heat your home.

Setback Setting

Setback Setting

Setback setting is designed to maintain a minimum level of comfort in a room when it is not occupied reducing unnecessary power usage.
airCore 700_6

Control your AC from anywhere with our airCloud Go* app!

Connect your airCore700 to airCloud Go via Wi-Fi and experience the freedom and convenience of saving energy and enhancing comfort. The app is available in 21 languages and offers features such as Voice Control, Operation Schedular and Quick Setup.


*airCloud Go SmartFence & Energy Monitoring not available with airCore700

airCore 700_7

Premium Zoning Systems with Modulating Damper Control

The Premium Zoning Kit is compatible with the airCore700 ducted system, designed for both medium-static (small homes) and high-static (large homes) indoor units.


Individual Room Temperature Setpoint
Allow connection up to 8 zones. Possible to connect each zone with Thermostat for comfort control.


Capable of optimising airflow into each zone
Optimising comfort with modulating damper control for each zone and regulates airflow based on set point temperature on thermostat.


Zoning Control



  • PC-ARFG2-Z controller enables central control of all zones through the Premium Zoning Kit. When enabled, the home screen with zone control icon and set temperature in each zone will be displayed.

  • Monitoring all individual zone status is available from the zone control screen. ON/OFF, Set temperature, Fan speed can be set for each individual zone from PC-ARFG2-Z.

  • Weekly operation schedule can be set to control the zoning system. Individual zones can be selected to program different operation times and temperatures in each.

airCore 700_8

R32 DC inverter compressor

Introducing the new R32 DC inverter compressor, featuring Hitachi's cutting-edge compressor control technology for enhanced energy efficiency. This compressor offers advanced pre-heating in low outdoor ambient temperatures through multi-pulse control on the coil, core, rotor, and stator, eliminating the need for an external crankcase heater. This innovation significantly improves pre-heating efficiency in low ambient conditions and reduces startup time. Features a newly improved refrigerant path and a new fin shape, making the unit more efficient.

airCore 700_9

Smart design makes installation easy

The outdoor unit of airCore 700 is designed with piping options available in four directions, allowing for flexible installation based on the specific situation. The unit accommodates up to 75m of piping run and 30m in height, this offers a great deal of flexibility in terms of installation.

Standard Home (Mid-Static)

IDU

PPIM-2.0UFA1NQ PPIM-2.5UFA1NQ PPIM-3.0UFA1NQ PPIM-4.0UFA1NQ PPIM-4.0UFA1NQ PPIM-5.0UFA1NQ PPIM-5.0UFA1NQ PPIM-6.0UFA1NQ PPIM-6.0UFA1NQ
ODU
Cooling Rated Capacity kW
Capacity Range[Min~Max] kW
Heating Rated Capacity kW
Capacity Range[Min~Max] kW
PAS-2.0UFASNQ1
5
1.5~6.0
6
1.5~7.5
PAS-2.5UFASNQ1
6
1.5~7.5
7.5
1.5~9.0
PAS-3.0UFASNQ1
7.2
2.5~8.6
8.6
3.5~10.4
PAS-4.0UFASNQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-4.0UFASMQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-5.0UFASNQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-5.0UFASMQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-6.0UFASNQ1
14
5.0~16.0
16
5.5~18.0
PAS-6.0UFASMQ1
14
5.0~16.0
16
5.5~18.0

Large Home (High-Static)

IDU

PPIH-3.0UFA1NQ PPIH-4.0UFA1NQ PPIH-4.0UFA1NQ PPIH-5.0UFA1NQ PPIH-5.0UFA1NQ PPIH-6.0UFA1NQ PPIH-6.0UFA1NQ PPIH-6.5UFA1NQ PPIH-6.5UFA1NQ
ODU
Cooling Rated Capacity kW
Capacity Range[Min~Max] kW
Heating Rated Capacity kW
Capacity Range[Min~Max] kW
PAS-3.0UFASNQ1
7.2
2.5~8.6
8.6
3.5~10.4
PAS-4.0UFASNQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-4.0UFASMQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-5.0UFASNQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-5.0UFASMQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-6.0UFASNQ1
14
5.0~16.0
16
5.5~18.0
PAS-6.0UFASMQ1
14
5.0~16.0
16
5.5~18.0
PAS-6.5UFASNQ1
16
6.0~18.0
18
6.5~20.0
PAS-6.5UFASMQ1
16
6.0~18.0
18
6.5~20.0

Documentation

Manuals, brochures and other product literature. If you need any more information, please get in touch.

Standard Home (Mid-Static)

IDU

PPIM-2.0UFA1NQ PPIM-2.5UFA1NQ PPIM-3.0UFA1NQ PPIM-4.0UFA1NQ PPIM-4.0UFA1NQ PPIM-5.0UFA1NQ PPIM-5.0UFA1NQ PPIM-6.0UFA1NQ PPIM-6.0UFA1NQ
ODU
Cooling Rated Capacity kW
Capacity Range[Min~Max] kW
Heating Rated Capacity kW
Capacity Range[Min~Max] kW
PAS-2.0UFASNQ1
5
1.5~6.0
6
1.5~7.5
PAS-2.5UFASNQ1
6
1.5~7.5
7.5
1.5~9.0
PAS-3.0UFASNQ1
7.2
2.5~8.6
8.6
3.5~10.4
PAS-4.0UFASNQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-4.0UFASMQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-5.0UFASNQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-5.0UFASMQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-6.0UFASNQ1
14
5.0~16.0
16
5.5~18.0
PAS-6.0UFASMQ1
14
5.0~16.0
16
5.5~18.0

Large Home (High-Static)

IDU

PPIH-3.0UFA1NQ PPIH-4.0UFA1NQ PPIH-4.0UFA1NQ PPIH-5.0UFA1NQ PPIH-5.0UFA1NQ PPIH-6.0UFA1NQ PPIH-6.0UFA1NQ PPIH-6.5UFA1NQ PPIH-6.5UFA1NQ
ODU
Cooling Rated Capacity kW
Capacity Range[Min~Max] kW
Heating Rated Capacity kW
Capacity Range[Min~Max] kW
PAS-3.0UFASNQ1
7.2
2.5~8.6
8.6
3.5~10.4
PAS-4.0UFASNQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-4.0UFASMQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-5.0UFASNQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-5.0UFASMQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-6.0UFASNQ1
14
5.0~16.0
16
5.5~18.0
PAS-6.0UFASMQ1
14
5.0~16.0
16
5.5~18.0
PAS-6.5UFASNQ1
16
6.0~18.0
18
6.5~20.0
PAS-6.5UFASMQ1
16
6.0~18.0
18
6.5~20.0

Standard Home (Mid-Static)

IDU

PPIM-2.0UFA1NQ PPIM-2.5UFA1NQ PPIM-3.0UFA1NQ PPIM-4.0UFA1NQ PPIM-4.0UFA1NQ PPIM-5.0UFA1NQ PPIM-5.0UFA1NQ PPIM-6.0UFA1NQ PPIM-6.0UFA1NQ
ODU
Cooling Rated Capacity kW
Capacity Range[Min~Max] kW
Heating Rated Capacity kW
Capacity Range[Min~Max] kW
PAS-2.0UFASNQ1
5
1.5~6.0
6
1.5~7.5
PAS-2.5UFASNQ1
6
1.5~7.5
7.5
1.5~9.0
PAS-3.0UFASNQ1
7.2
2.5~8.6
8.6
3.5~10.4
PAS-4.0UFASNQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-4.0UFASMQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-5.0UFASNQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-5.0UFASMQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-6.0UFASNQ1
14
5.0~16.0
16
5.5~18.0
PAS-6.0UFASMQ1
14
5.0~16.0
16
5.5~18.0

Large Home (High-Static)

IDU

PPIH-3.0UFA1NQ PPIH-4.0UFA1NQ PPIH-4.0UFA1NQ PPIH-5.0UFA1NQ PPIH-5.0UFA1NQ PPIH-6.0UFA1NQ PPIH-6.0UFA1NQ PPIH-6.5UFA1NQ PPIH-6.5UFA1NQ
ODU
Cooling Rated Capacity kW
Capacity Range[Min~Max] kW
Heating Rated Capacity kW
Capacity Range[Min~Max] kW
PAS-3.0UFASNQ1
7.2
2.5~8.6
8.6
3.5~10.4
PAS-4.0UFASNQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-4.0UFASMQ1
10
3.2~12.0
11.5
3.5~14.0
PAS-5.0UFASNQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-5.0UFASMQ1
12.5
4.0~14.2
14
4.0~16.2
PAS-6.0UFASNQ1
14
5.0~16.0
16
5.5~18.0
PAS-6.0UFASMQ1
14
5.0~16.0
16
5.5~18.0
PAS-6.5UFASNQ1
16
6.0~18.0
18
6.5~20.0
PAS-6.5UFASMQ1
16
6.0~18.0
18
6.5~20.0