– RAF Floor Mounted air conditioner
Floor Mounted Inverter Heat Pump AC
– RAF Floor Mounted air conditioner
Floor Mounted Inverter Heat Pump AC
A system for all seasons, floor-standing split system air conditioners are an effective choice when wall space is limited.

– An air conditioner with Intelligent Airflow
Floor Mounted split system deflectors intelligently direct cold air up and hot air down, setting the perfect temperature quickly and efficiently - without blowing air directly at room occupants.
– Fresher Air with Hitachi Air Conditioning

– Energy Efficient Comfort
Hitachi Floor Mount air conditioners deliver low-energy heating and cooling by utilising high-efficiency inverter compressor technology.
Hitachi Inverter compressors will use less energy as the floor-mounted system slows down as the room reaches its set temperature.
Hitachi Inverter compressors will use less energy as the floor-mounted system slows down as the room reaches its set temperature.

– Superior technology from the ground up
Compact and extremely efficient, Hitachi's inverter floor -standing split system air conditioners are ideal if you want to position your ac unit at floor level - either by preference or because you wish to avoid using a wall-mounted unit on an apartment common wall.
These AC units efficiently distribute air right across your entire room.
The Power Active Module (PAM) Inverter system minimises power losses and ensures efficiency even when temperatures drop below -15°C. With the Twin Inverter rotary compressor, you can be assured of a smoother quieter operation.
These AC units efficiently distribute air right across your entire room.
The Power Active Module (PAM) Inverter system minimises power losses and ensures efficiency even when temperatures drop below -15°C. With the Twin Inverter rotary compressor, you can be assured of a smoother quieter operation.
– Add Cooling to your Heating
Hitachi's floor standing split system is the perfect fit for your fireplace or ideal when replacing a gas heater.
It can even be semi-recessed into the wall. So you can enjoy heating and cooling from one efficient unit.
It can even be semi-recessed into the wall. So you can enjoy heating and cooling from one efficient unit.

– Peace of Mind
Backed by one of Australia's largest manufacturers, Temperzone -- you will always have peace of mind with a five-year warranty on parts and labour.
– Model
Model
RAF-35NXA1/RAC-35NXA1 | RAF-50NXA1/RAC-50NXA1 |
---|

Capacity | Nominal Cooling | kW |
Nominal Heating | kW |
Capacity (Range) | Cooling | kW |
Heating | kW |
Airflow | l/sec |
Energy Efficiency | EER / AEER Cooling | |
COP / ACOP Heating | ||
Star Rating Cooling | ||
Star Rating Heating |
Noise Levels (dB(A)) Cooling | Indoor Unit | Hi/Med/Low/Sleep |
Outdoor Unit | Cooling/Heating |
Dimensions (mm) | Indoor Unit | (WxHxD) |
Outdoor Unit | (WxHxD) |
Weights (kg) | Indoor / Outdoor |
Operating Range | Outdoor Op. Temp. | Cooling |
Outdoor Op. Temp. | Heating |
Refrigerant Type |
Pipe Sizes (mm) | ||
Refrig Pipe charge | ||
Min / Max Pipe Lgth / Lift (m) |
Power | Power Supply | |
Run Amps at 230v | Cooling / Heating | |
Power Supply To | ||
Rec. Circuit Breaker (A) | ||
Interconnecting Wire |
3.5 |
4.2 |
1.1-4.2 |
1.1-5.2 |
167 |
3.80/3.74 |
3.95/3.89 |
2.5 |
3 |
42/35/29/25 |
47/49 |
760 x 600 x 235 |
841 x 548 x 335 |
14 / 36 |
-10°C to 43°C |
-15°C to 21°C |
R410A |
Ø9.50 / Ø6.35 |
20 |
3 / 20 / 10 |
230 - 240 Volt / 50 Hz / 1 Phase |
4.80 / 4.90 |
Outdoor Unit |
16 |
1.5mm 2 Core + E |
5.0 |
6.0 |
1.1-5.2 |
2.2-7.3 |
180 |
3.33/3.29 |
3.87/3.83 |
2 |
3 |
46/37/30/25 |
52/52 |
760 x 600 x 235 |
887 x 600 x 345 |
14 / 40 |
-10°C to 43°C |
-15°C to 21°C |
R410A |
Ø12.7 / Ø6.35 |
20 |
3 / 20 / 10 |
230 - 240 Volt / 50 Hz / 1 Phase |
6.20 / 7.00 |
Outdoor Unit |
16 |
1.5mm 2 Core + E |
– Documentation
Manuals, brochures and other product literature. If you need any more information, please get in touch.
– Model
Model
RAF-35NXA1/RAC-35NXA1 | RAF-50NXA1/RAC-50NXA1 |
---|

Capacity | Nominal Cooling | kW |
Nominal Heating | kW |
Capacity (Range) | Cooling | kW |
Heating | kW |
Airflow | l/sec |
Energy Efficiency | EER / AEER Cooling | |
COP / ACOP Heating | ||
Star Rating Cooling | ||
Star Rating Heating |
Noise Levels (dB(A)) Cooling | Indoor Unit | Hi/Med/Low/Sleep |
Outdoor Unit | Cooling/Heating |
Dimensions (mm) | Indoor Unit | (WxHxD) |
Outdoor Unit | (WxHxD) |
Weights (kg) | Indoor / Outdoor |
Operating Range | Outdoor Op. Temp. | Cooling |
Outdoor Op. Temp. | Heating |
Refrigerant Type |
Pipe Sizes (mm) | ||
Refrig Pipe charge | ||
Min / Max Pipe Lgth / Lift (m) |
Power | Power Supply | |
Run Amps at 230v | Cooling / Heating | |
Power Supply To | ||
Rec. Circuit Breaker (A) | ||
Interconnecting Wire |
3.5 |
4.2 |
1.1-4.2 |
1.1-5.2 |
167 |
3.80/3.74 |
3.95/3.89 |
2.5 |
3 |
42/35/29/25 |
47/49 |
760 x 600 x 235 |
841 x 548 x 335 |
14 / 36 |
-10°C to 43°C |
-15°C to 21°C |
R410A |
Ø9.50 / Ø6.35 |
20 |
3 / 20 / 10 |
230 - 240 Volt / 50 Hz / 1 Phase |
4.80 / 4.90 |
Outdoor Unit |
16 |
1.5mm 2 Core + E |
5.0 |
6.0 |
1.1-5.2 |
2.2-7.3 |
180 |
3.33/3.29 |
3.87/3.83 |
2 |
3 |
46/37/30/25 |
52/52 |
760 x 600 x 235 |
887 x 600 x 345 |
14 / 40 |
-10°C to 43°C |
-15°C to 21°C |
R410A |
Ø12.7 / Ø6.35 |
20 |
3 / 20 / 10 |
230 - 240 Volt / 50 Hz / 1 Phase |
6.20 / 7.00 |
Outdoor Unit |
16 |
1.5mm 2 Core + E |