– airHome 400
Wall Mounted Inverter Heat Pump AC
– airHome 400
Wall Mounted Inverter Heat Pump AC
Home air conditioning that’s easy to use, makes daily life more convenient, and comes with integrated self-maintenance technology that help to improves the long-term performance of the unit. airHome is the air conditioner for people who don’t want to think about air conditioning.
– Adjusts temperature as you arrive home or leave the house
Use the airCloud Go smartphone app to set up location awareness and temperature profiles, for example, detecting when you are on your way home and automatically adjusting the temperature ready for your arrival.
With the airCloud Go app you can also connect to your smart speaker (compatible with Amazon Echo and Google Home), use weekly schedule and timer functions and see how much power has been consumed with the integrated Energy Cost Estimator.
With the airCloud Go app you can also connect to your smart speaker (compatible with Amazon Echo and Google Home), use weekly schedule and timer functions and see how much power has been consumed with the integrated Energy Cost Estimator.
– 3X better at maintaining the performance of your air conditioner
Over time dust and dirt can build up in your air conditioning unit reducing the amount of air that can flow through it and making it less powerful.
Hitachi FrostWash technology helps to maintain the performance of your air conditioner for years to come by freezing dust and dirt, melting it and washing it away. Our tests show that systems with FrostWash are 3X better at maintaining air flow performance than those without this technology[1].
Hitachi FrostWash technology helps to maintain the performance of your air conditioner for years to come by freezing dust and dirt, melting it and washing it away. Our tests show that systems with FrostWash are 3X better at maintaining air flow performance than those without this technology[1].
– Stop the causes of air conditioning odours
Whenever the unit is switched off, the mould guard function automatically blows air through internal components to prevent the build-up of mould – the primary cause of those nasty odours.
– Japanese quality, built to last
Hot and cold shock, extreme humidity, torrential rain, voltage surges, lightning strikes, impacts and more… every air conditioner we sell has been tested to the extreme. In addition, our unique SafeGuard System combines electrical and mechanical systems to protect the outdoor unit from extreme weather and voltage fluctuation. These protections include a 3-minute delay circuit to prevent damage caused by multiple fast re-starts in the event of power cuts, an outdoor unit valve cover to channel water and condensation safely away from the outdoor unit, anti-rust paint and heat fins, and a metal fireproof electrical enclosure to protect electronics inside the outdoor unit.
– Helps to purify your indoor air
Combining 3 different air purification technologies for enhanced effectiveness against pollutants including viruses and bacteria and even odors. The pre-filter, air purification filter and heat exchange cleaner work together with up to 99.0% effectiveness on viruses[2], up to 99.0% effectiveness on bacteria[3]
– Vector DC Inverter technology
Our Cascade Vector DC Inverter System is equipped with a microchip to control the speed of the compressor. A split rotor with displaced electrical poles enables electromagnetic noise suppression and optimises low-speed energy-efficiency.
With inverter technology, an air conditioner cools with maximum capacity at start-up, then automatically slows down and operates at a minimal capacity to maintain room temperature at a comfortable level. Non-inverter models can only operate with simple on-off controls. Trying to maintain the desired temperature by repeatedly switching power on and off consumes much more electricity and results in bigger temperature fluctuations.
With inverter technology, an air conditioner cools with maximum capacity at start-up, then automatically slows down and operates at a minimal capacity to maintain room temperature at a comfortable level. Non-inverter models can only operate with simple on-off controls. Trying to maintain the desired temperature by repeatedly switching power on and off consumes much more electricity and results in bigger temperature fluctuations.
– Other Benefits
Silent Mode
Specially curved fan blades reduce the noise of them cutting through the air at slower speeds.
0.5°C temperature control
Set temperature in increments of 0.5°C
Multiple Timers
6x On/Off time and temperature settings for each day of the week (using airCloud Go). Set a specific time interval for power off, up to 12 hours
Save your favorite settings
Quickly activate your most-used combination of mode, temperature and fan speed with a dedicated button on the remote control
– Technical specifications
Indoor / Outdoor Unit
RAK-DJ18PHAE / RAC-DJ18PHAE | RAK-DJ25PHAE / RAC-DJ25PHAE | RAK-DJ35PHAE / RAC-DJ35PHAE | RAK-DJ50PHAE / RAC-DJ50PHAE |
---|
Nominal Capacity (Min. - Max.) | Cooling | kW |
Heating | kW |
Energy efficiency | SEER | |
SCOP |
Energy Rating (Energy class) | Cooling | |
Heating |
Heating function | For winter heating |
airCloud Go | App for remote control & scheduling |
FrostWash | Maintains airflow performance |
Mold Guard Function | Prevents build-up of mold |
Smart Eco | Automated power saving |
Air Purification Filter | ViroSense Z1 filter |
FrostWash | automatic self-cleaning |
Ionizer | AQtiv-Ion |
Power Supply | V / Phase / Hz |
Nominal Cooling Power Input (Min. - Max.) | Watts |
Nominal Heating Power Input (Min. - Max.) | Watts |
Starting Current (cooling/heating) | Amps |
Running Current (cooling/heating) | Amps |
Operation Range | Cooling | ºC |
Heating | ºC |
Refrigerant | Type | |
Current Amount | kg |
Compressor Type |
Diameter of Pipes | Liquid | Inch |
Gas | Inch |
Maximum Pipe Length | m |
Maximum Piping Elevation | m |
Dehumidification | l / h |
Indoor Unit | Height | mm |
Width | mm | |
Depth | mm | |
Weight | kg | |
Air Flow (Max.) | m3 / h | |
Sound Power | dB(A) | |
Sound Pressure | dB(A) |
Outdoor Unit | Height | mm |
Width | mm | |
Depth | mm | |
Weight | kg | |
Sound Power | dB(A) | |
Sound Pressure | dB(A) |
2.00 (0.90 - 2.50) |
2.50 (0.90 - 3.20) |
7.5 |
4.6 |
A++ |
A++ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
220-240V / 1Ph / 50Hz |
0.58(0.25-1.01) |
0.595(0.25-0.97) |
3.22/3.51 |
1.09-4.39/1.09-4.22 |
-10 ~ 46 |
-15 ~ 21 |
R32 |
0.58 |
Rotary |
1/4" |
3/8" |
20 |
10 |
1.2 |
280 |
780 |
222 |
7.7 |
545 |
51 |
20/24/30/34/38 |
530 |
660 |
278 |
23 |
59 |
46 |
2.50 (0.90 - 3.10) |
3.40 (0.90- 4.40) |
7.5 |
4.6 |
A++ |
A++ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
220-240V / 1Ph / 50Hz |
0.70 (0.25 - 1.29) |
0.85 (0.25 - 1.25) |
3.89/4.53 |
1.09-5.61/1.09-5.43 |
-10 ~ 46 |
-15 ~ 21 |
R32 |
0.58 |
Rotary |
1/4" |
3/8" |
20 |
10 |
1.4 |
280 |
780 |
222 |
7.7 |
620 |
54 |
20/25/31/36/41 |
530 |
660 |
278 |
23 |
61 |
48 |
3.50 (0.90- 4.00) |
4.20 (0.90- 5.00) |
7.5 |
4.6 |
A++ |
A++ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
220-240V / 1Ph / 50Hz |
1.084 (0.25 - 1.46) |
1.050(0.25 - 1.70) |
5.38/5.30 |
1.09-6.35/1.09-7.39 |
-10 ~ 46 |
-15 ~ 21 |
R32 |
0.72 |
Rotary |
1/4" |
3/8" |
20 |
10 |
1.6 |
280 |
780 |
222 |
7.7 |
653 |
57 |
20/28/36/40/44 |
530 |
660 |
278 |
24.4 |
62 |
49 |
5.00 (1.90- 5.20) |
6.00 (2.20- 7.30) |
7.0 |
4.5 |
A++ |
A+ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
220-240V / 1Ph / 50Hz |
1.548(0.50 - 2.10) |
1.617(0.50 - 2.75) |
7.11/7.42 |
2.17-9.13/2.17-11.96 |
-10 ~ 46 |
-15 ~ 21 |
R32 |
0.93 |
2 Cylinder Rotary |
1/4" |
3/8" |
20 |
10 |
2 |
280 |
780 |
222 |
8.4 |
663 |
60 |
25/31/37/42/47 |
600 |
792 |
299 |
39.1 |
64 |
51 |
– Documentation
Manuals, brochures and other product literature. If you need any more information, please get in touch.
– Technical specifications
Indoor / Outdoor Unit
RAK-DJ18PHAE / RAC-DJ18PHAE | RAK-DJ25PHAE / RAC-DJ25PHAE | RAK-DJ35PHAE / RAC-DJ35PHAE | RAK-DJ50PHAE / RAC-DJ50PHAE |
---|
Nominal Capacity (Min. - Max.) | Cooling | kW |
Heating | kW |
Energy efficiency | SEER | |
SCOP |
Energy Rating (Energy class) | Cooling | |
Heating |
Heating function | For winter heating |
airCloud Go | App for remote control & scheduling |
FrostWash | Maintains airflow performance |
Mold Guard Function | Prevents build-up of mold |
Smart Eco | Automated power saving |
Air Purification Filter | ViroSense Z1 filter |
FrostWash | automatic self-cleaning |
Ionizer | AQtiv-Ion |
Power Supply | V / Phase / Hz |
Nominal Cooling Power Input (Min. - Max.) | Watts |
Nominal Heating Power Input (Min. - Max.) | Watts |
Starting Current (cooling/heating) | Amps |
Running Current (cooling/heating) | Amps |
Operation Range | Cooling | ºC |
Heating | ºC |
Refrigerant | Type | |
Current Amount | kg |
Compressor Type |
Diameter of Pipes | Liquid | Inch |
Gas | Inch |
Maximum Pipe Length | m |
Maximum Piping Elevation | m |
Dehumidification | l / h |
Indoor Unit | Height | mm |
Width | mm | |
Depth | mm | |
Weight | kg | |
Air Flow (Max.) | m3 / h | |
Sound Power | dB(A) | |
Sound Pressure | dB(A) |
Outdoor Unit | Height | mm |
Width | mm | |
Depth | mm | |
Weight | kg | |
Sound Power | dB(A) | |
Sound Pressure | dB(A) |
2.00 (0.90 - 2.50) |
2.50 (0.90 - 3.20) |
7.5 |
4.6 |
A++ |
A++ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
220-240V / 1Ph / 50Hz |
0.58(0.25-1.01) |
0.595(0.25-0.97) |
3.22/3.51 |
1.09-4.39/1.09-4.22 |
-10 ~ 46 |
-15 ~ 21 |
R32 |
0.58 |
Rotary |
1/4" |
3/8" |
20 |
10 |
1.2 |
280 |
780 |
222 |
7.7 |
545 |
51 |
20/24/30/34/38 |
530 |
660 |
278 |
23 |
59 |
46 |
2.50 (0.90 - 3.10) |
3.40 (0.90- 4.40) |
7.5 |
4.6 |
A++ |
A++ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
220-240V / 1Ph / 50Hz |
0.70 (0.25 - 1.29) |
0.85 (0.25 - 1.25) |
3.89/4.53 |
1.09-5.61/1.09-5.43 |
-10 ~ 46 |
-15 ~ 21 |
R32 |
0.58 |
Rotary |
1/4" |
3/8" |
20 |
10 |
1.4 |
280 |
780 |
222 |
7.7 |
620 |
54 |
20/25/31/36/41 |
530 |
660 |
278 |
23 |
61 |
48 |
3.50 (0.90- 4.00) |
4.20 (0.90- 5.00) |
7.5 |
4.6 |
A++ |
A++ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
220-240V / 1Ph / 50Hz |
1.084 (0.25 - 1.46) |
1.050(0.25 - 1.70) |
5.38/5.30 |
1.09-6.35/1.09-7.39 |
-10 ~ 46 |
-15 ~ 21 |
R32 |
0.72 |
Rotary |
1/4" |
3/8" |
20 |
10 |
1.6 |
280 |
780 |
222 |
7.7 |
653 |
57 |
20/28/36/40/44 |
530 |
660 |
278 |
24.4 |
62 |
49 |
5.00 (1.90- 5.20) |
6.00 (2.20- 7.30) |
7.0 |
4.5 |
A++ |
A+ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
220-240V / 1Ph / 50Hz |
1.548(0.50 - 2.10) |
1.617(0.50 - 2.75) |
7.11/7.42 |
2.17-9.13/2.17-11.96 |
-10 ~ 46 |
-15 ~ 21 |
R32 |
0.93 |
2 Cylinder Rotary |
1/4" |
3/8" |
20 |
10 |
2 |
280 |
780 |
222 |
8.4 |
663 |
60 |
25/31/37/42/47 |
600 |
792 |
299 |
39.1 |
64 |
51 |