Hitachi
Where to buy
Hitachi
  • About us
  • Innovation
  • Magazine
  • Search
United Kingdom
Hitachi
  • Residential Product
  • Professional Product
  • Support Links
    • Business Applications
    • Downloads
    • Apps & Software
    • Virtual Showroom
    • FAQs
Contact us
Where to buy
Contact us
  • Air Conditioning
  • Heat Pumps
  • CASSETTE RAI
  • PREMIUM S SERIES WALL MOUNTED
  • PERFORMANCE RPE WALL MOUNTED
  • SHIROKUMA RXE WALL MOUNTED
  • MULTI-ZONE AIR CONDITIONING
  • RAD DUCTED
  • SUMMIT REF WALL MOUNTED
  • SHIROKUMA RAF CONSOLE
  • Light Commercial RPE Wall Mounted
airHome
See all products
  • YUTAKI M
  • YUTAKI S80
  • YUTAKI S COMBI
  • YUTAKI S
See all products
  • Commercial AC
  • VRF Systems
  • Chillers
  • Air Renewal
  • IVX COMFORT
  • PRIMAIRY R32
  • IVX Prime
See all products
  • SET FREE MINI
  • SET FREE SIGMA
  • CENTRIFUGAL VRF
See all products
  • WH1 WATER-WATER CHILLER
  • CLH1 REMOTE CONDENSER CHILLER
  • AH2 AIR-WATER CHILLER
See all products
  • KPI
  • ECONOFRESH
  • ACTIVE KPI
See all products
Residential Product
Air Conditioning
  • CASSETTE RAI
  • PREMIUM S SERIES WALL MOUNTED
  • PERFORMANCE RPE WALL MOUNTED
  • SHIROKUMA RXE WALL MOUNTED
  • MULTI-ZONE AIR CONDITIONING
  • RAD DUCTED
  • SUMMIT REF WALL MOUNTED
  • SHIROKUMA RAF CONSOLE
  • Light Commercial RPE Wall Mounted
airHome
See all products
Heat Pumps
  • YUTAKI M
  • YUTAKI S80
  • YUTAKI S COMBI
  • YUTAKI S
See all products
Professional Product
Commercial AC
  • IVX COMFORT
  • PRIMAIRY R32
  • IVX Prime
See all products
VRF Systems
  • SET FREE MINI
  • SET FREE SIGMA
  • CENTRIFUGAL VRF
See all products
Chillers
  • WH1 WATER-WATER CHILLER
  • CLH1 REMOTE CONDENSER CHILLER
  • AH2 AIR-WATER CHILLER
See all products
Air Renewal
  • KPI
  • ECONOFRESH
  • ACTIVE KPI
See all products
Support Links
  • Business Applications
  • Downloads
  • Apps & Software
  • Virtual Showroom
  • FAQs
Choose your country or region
United Kingdom
—
  • Australia
  • Oman
  • Sverige
  • Bahrain
  • Egypt
  • Iraq
  • Jordan
  • Kuwait
  • Libya
  • Pakistan
  • Việt Nam
  • Palestine
  • Qatar
  • Saudi Arabia
  • UAE
  • 香港特別行政區
  • Indonesia (Indonesian)
  • ประเทศไทย
  • Vietnam
  • United States & Canada
  • България
  • Indonesia
  • Brasil
  • Česká republika
  • Deutschland
  • España
  • France
  • Hong Kong SAR, China
  • Magyarország
  • India
  • Türkiye
  • Italia
  • Malaysia
  • New Zealand
  • Polska
  • Россия
  • Singapore
  • Slovensko
  • Thailand
  • Sri-Lanka
  1. Hitachi
  2. Ranges
  3. Air Conditioning
  4. CASSETTE RAI

– CASSETTE RAI

For the most effective air distribution
CASSETTE RAI_header
CASSETTE RAI_0

– Flexible air flow

The unit delivers excellent coverage with a wide distribution of air, making it ideal for use in large spaces.

Individual louvre control directs the air wherever its required for maximum comfort.

– Eco-friendly high performance

The unit uses environmentally friendly R32 refrigerant deliverying SEER up to 6.50 for A++ Energy ratings and lower running costs.
CASSETTE RAI_2

– Motion detection

Units come with motion detectors as standard which automatically switches to eco mode when no people are detected and then switches back to standard mode when someone enters the room.

Lowers running costs and increases energy efficiency.

– Custom control

CASSETTE RAI_3

– Outdoor Units

Light Commercial Cassette

RAI-25RPE RAI-35RPE RAI-50RPE RAI-60RPE
Nominal Capacity (min - max) Cooling KW
Heating KW
Seasonal energy rating Cooling
Heating
SEER
SCOP
EER - COP (Cooling/heating energy label)
Sound Pressure (very low - low - med - high) Cooling dB(A)
Heating dB(A)
Sound Power (Eurovent data) dB(A)
Air flow (very low - low - med - high) Cooling m3/h
Heating m3/h
Diameter of pipes (liquid-gas) Inches
Condensate drain diameter mm
Remote control (standard)
Programming
Dimensions Height mm
Width mm
Depth mm
Cassette panel dimensions Height mm
Width mm
Depth mm
Weight kg
2,50 (0,90-3,00)
3,50 (0,90-5,00)
A++
A+
6.20
4.30
4,20-4,00 (A/A)
27-31-35-38
28-32-36-39
54
360-505-590-660
444-540-630-720
1/4 - 3/8
32
Eco Control
24h / 7 day
285
570
570
30
620
620
20
3,50 (0,90-4,00)
4,80 (0,90-6,60)
A++
A+
6.50
4.30
4,00-3,90 (A/A)
27-33-37-40
28-34-38-41
56
360-505-590-660
444-540-630-720
1/4 - 3/8
32
Eco Control
24h / 7 day
285
570
570
30
620
620
20
5,00 (1,20-5,80)
6,00 (1,20-6,80)
A++
A+
6.20
4.40
3,52-3,82 (A/A)
29-35-39-43
30-36-40-44
56
390-540-630-720
450-600-690-780
1/4 - 1/2
32
Eco Control
24h / 7 day
285
570
570
30
620
620
20
6,00 (1,20-6,50)
7,00 (1,20-6,50)
A++
A+
6.20
4.40
3,51-3,80 (A/A)
29-35-39-43
30-36-40-44
56
390-540-630-720
450-600-690-780
1/4 - 1/2
32
Eco Control
24h / 7 day
285
570
570
30
620
620
20

Outdoor Units

RAC-25NPE RAC-35NPE RAC-50NPE RAC-60NPE
Power feed
Power consumption (min - max) Cooling KW
Heating KW
Sound Pressure Cooling dB(A)
Heating dB(A)
Sound Power dB(A)
Airflow Cooling m3/h
Heating m3/h
Diameter of pipes (liquid-gas) Inches
Maximum pipe length m
Maximum piping elevation (between IDU & ODU) m
Refrigerant charge / (Pre-charged length) kg (m)
Refrigerant
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight kg
220-240V, 1Ph, 50Hz
0,60 (0,25-1,29)
0,88 (0,25-1,50)
48
49
61
1920
1620
1/4 - 3/8
20
10
0,86 (20)
R32
Rotary
548
750
288
32.5
220-240V, 1Ph, 50Hz
0,88 (0,25-1,46)
1,23 (0,25-1,92)
48
49
61
1920
1620
1/4 - 3/8
20
10
0,86 (20)
R32
Rotary
548
750
288
32.5
220-240V, 1Ph, 50Hz
1,42 (0,30-2,50)
1,57 (0,30-2,65)
50
53
65
2160
2160
1/4 - 1/2
30
20
1,5 (30)
R32
2 Cylinder Rotary
750
850
298
50
220-240V, 1Ph, 50Hz
1,71 (0,30-2,60)
1,84 (0,30-2,65)
50
53
65
2160
2160
1/4 - 1/2
30
20
1,5 (30)
R32
2 Cylinder Rotary
750
850
298
50
Open table
Download PDF
Download PDF

– Documentation

Manuals, brochures and other product literature. If you need any more information, please get in touch.
IM - RAI RPE
IM - RAC 25 & 35 NPE
IM - RAC 50 & 60 NPE
Technical Catalogue - Light Commercial Cassette & Ducts
All downloads
– Where to buy
Learn more
– How can we help you?
If you need product or project advice, technical support, or have any other questions, we're here to help.
Contact us

– Outdoor Units

Light Commercial Cassette

RAI-25RPE RAI-35RPE RAI-50RPE RAI-60RPE
Nominal Capacity (min - max) Cooling KW
Heating KW
Seasonal energy rating Cooling
Heating
SEER
SCOP
EER - COP (Cooling/heating energy label)
Sound Pressure (very low - low - med - high) Cooling dB(A)
Heating dB(A)
Sound Power (Eurovent data) dB(A)
Air flow (very low - low - med - high) Cooling m3/h
Heating m3/h
Diameter of pipes (liquid-gas) Inches
Condensate drain diameter mm
Remote control (standard)
Programming
Dimensions Height mm
Width mm
Depth mm
Cassette panel dimensions Height mm
Width mm
Depth mm
Weight kg
2,50 (0,90-3,00)
3,50 (0,90-5,00)
A++
A+
6.20
4.30
4,20-4,00 (A/A)
27-31-35-38
28-32-36-39
54
360-505-590-660
444-540-630-720
1/4 - 3/8
32
Eco Control
24h / 7 day
285
570
570
30
620
620
20
3,50 (0,90-4,00)
4,80 (0,90-6,60)
A++
A+
6.50
4.30
4,00-3,90 (A/A)
27-33-37-40
28-34-38-41
56
360-505-590-660
444-540-630-720
1/4 - 3/8
32
Eco Control
24h / 7 day
285
570
570
30
620
620
20
5,00 (1,20-5,80)
6,00 (1,20-6,80)
A++
A+
6.20
4.40
3,52-3,82 (A/A)
29-35-39-43
30-36-40-44
56
390-540-630-720
450-600-690-780
1/4 - 1/2
32
Eco Control
24h / 7 day
285
570
570
30
620
620
20
6,00 (1,20-6,50)
7,00 (1,20-6,50)
A++
A+
6.20
4.40
3,51-3,80 (A/A)
29-35-39-43
30-36-40-44
56
390-540-630-720
450-600-690-780
1/4 - 1/2
32
Eco Control
24h / 7 day
285
570
570
30
620
620
20

Outdoor Units

RAC-25NPE RAC-35NPE RAC-50NPE RAC-60NPE
Power feed
Power consumption (min - max) Cooling KW
Heating KW
Sound Pressure Cooling dB(A)
Heating dB(A)
Sound Power dB(A)
Airflow Cooling m3/h
Heating m3/h
Diameter of pipes (liquid-gas) Inches
Maximum pipe length m
Maximum piping elevation (between IDU & ODU) m
Refrigerant charge / (Pre-charged length) kg (m)
Refrigerant
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight kg
220-240V, 1Ph, 50Hz
0,60 (0,25-1,29)
0,88 (0,25-1,50)
48
49
61
1920
1620
1/4 - 3/8
20
10
0,86 (20)
R32
Rotary
548
750
288
32.5
220-240V, 1Ph, 50Hz
0,88 (0,25-1,46)
1,23 (0,25-1,92)
48
49
61
1920
1620
1/4 - 3/8
20
10
0,86 (20)
R32
Rotary
548
750
288
32.5
220-240V, 1Ph, 50Hz
1,42 (0,30-2,50)
1,57 (0,30-2,65)
50
53
65
2160
2160
1/4 - 1/2
30
20
1,5 (30)
R32
2 Cylinder Rotary
750
850
298
50
220-240V, 1Ph, 50Hz
1,71 (0,30-2,60)
1,84 (0,30-2,65)
50
53
65
2160
2160
1/4 - 1/2
30
20
1,5 (30)
R32
2 Cylinder Rotary
750
850
298
50
Open table
Download PDF
Download PDF
Equipment
  • Air Conditioning
  • Air Renewal
  • Chillers
  • Commercial AC
  • Heat Pumps
  • VRF Systems
Useful links
  • Where to buy
  • Downloads
  • About us
  • Contact us
  • Hitachi Air Conditioner App
  • Magazine
  • Partner With Us
  • Sign in
  • European Factory Tour
  • Legal & Cookies Policies
  • Privacy Policy

© 2022 Johnson Controls - Hitachi Air Conditioning Company

Need help? Chat with us!
–