RAD Ducted

Ducted Inverter Heat Pump AC

RAD Ducted_header

RAD Ducted

Ducted Inverter Heat Pump AC

Discreet air conditioning
RAD Ducted_0

Concealed installation

Designed to fit into false ceilings, the system is ideal for installations where the units are best hidden. Up to 150Pa of static pressure ensures distribution of a large volume of air guaranteeing maximum comfort and felxible ductwork solutions.

Premium energy efficiency

Eco-friendly R32 refrigerant delivers high performance and running cost savings with a SEER rating up to 6.50 and an energy rating up to A++.

For all rooms

RAD Ducted_2

Outdoor Units

Light Commercial Ducted

RAD-25RPE RAD-35RPE RAD-50RPE RAD-60RPE RAD-70PPD
Nominal Capacity (min - max) Cooling KW
Heating KW
Seasonal energy rating Cooling
Heating
SEER
SCOP
EER - COP (Cooling/heating energy label)
Sound Pressure (very low - low - med - high) Cooling dB(A)
Heating dB(A)
Sound Power (Eurovent data) dB(A)
Air flow (very low - low - med - high) Cooling m3/h
Heating m3/h
Diameter of pipes (liquid-gas) Inches
Condensate drain diameter mm
Remote control (option)
Programming
Dimensions Height mm
Width mm
Depth mm
Weight kg
2,50 (0,90-3,00)
3,50 (0,90-5,50)
A++
A+
6.20
4.30
4,20-4,00 (A/A)
30-33-37-41
30-34-38-42
57
330-390-450-510
330-390-450-510
1/4 - 3/8
16
Eco Control
7 Day / 24 Hr
235
750
400
16
3,50 (0,90-4,00)
4,80 (0,90-6,60)
A++
A+
6.50
4.30
3,70-3,81 (A/A)
30-33-37-41
30-34-38-42
57
330-390-450-510
330-390-450-510
1/4 - 3/8
16
Eco Control
7 Day / 24 Hr
235
750
400
16
5,00 (1,20-5,80)
6,00 (1,20-6,80)
A++
A+
6.20
4.00
3,52-3,82 (A/A)
29-32-35-39
29-32-35-40
53
350-540-800-1140
350-540-800-1140
1/4 - 1/2
35
Eco Control
7 Day / 24 Hr
270
900
720
35
6,00 (1,20-6,50)
7,00 (1,20-8,00)
A++
A+
6.20
4.00
3,51-3,80 (A/A)
29-32-35-39
29-32-35-40
53
350-540-800-1140
350-540-800-1140
1/4 - 1/2
35
Eco Control
7 Day / 24 Hr
270
900
720
35
7,00 (1,50-8,00)
8,00 (1,50-8,50)
A++
A+
6.10
4.00
3,32-3,64 (A/A)
29-32-35-39
29-32-35-40
53
350-540-800-1140
350-540-800-1140
1/4 - 5/8
35
Eco Control
7 Day / 24 Hr
270
900
720
35

Outdoor Units

RAC-25NPE RAC-35NPE RAC 50NPE RAC-60NPE RAC-70NPD
Power feed
Power consumption (min - max) Cooling KW
Heating KW
Sound Pressure Cooling dB(A)
Heating dB(A)
Sound Power dB(A)
Airflow Cooling m3/h
Heating m3/h
Diameter of pipes (liquid-gas) Inches
Maximum pipe length m
Maximum piping elevation (between IDU & ODU) m
Refrigerant charge / (Pre-charged length) kg (m)
Refrigerant
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight kg
220-240V, 1Ph, 50Hz
0,60 (0,25-1,29)
0,88 (0,25-1,50)
48
49
61
1920
1620
1/4 - 3/8
20
10
0,86 (20)
R32
Rotary
548
750
288
33
220-240V, 1Ph, 50Hz
0,95 (0,25-1,46)
1,26 (0,25-1,92)
48
49
61
1920
1620
1/4 - 3/8
20
10
0,86 (20)
R32
Rotary
548
750
288
33
220-240V, 1Ph, 50Hz
1.42 (0,30-2,50)
1,50 (0,30-2,65)
50
53
65
2160
2160
1/4 - 1/2
30
20
1,50 (30)
R32
DC Twin Rotary
750
850
298
50
220-230V, 1Ph, 50Hz
1,71 (0,30-2,65)
1,84 (0,30-2,65)
50
53
65
2160
2160
1/4 - 1/2
30
20
1,50 (30)
R32
DC Twin Rotary
750
850
298
50
220-230V, 1Ph, 50Hz
2,11 (0,50-2,70)
2,20 (0,50-2,80)
50
53
65
2700
2700
1/4 - 5/8
30
20
1,60 (30)
R32
Rotary
800
850
298
52

Documentation

Manuals, brochures and other product literature. If you need any more information, please get in touch.

Outdoor Units

Light Commercial Ducted

RAD-25RPE RAD-35RPE RAD-50RPE RAD-60RPE RAD-70PPD
Nominal Capacity (min - max) Cooling KW
Heating KW
Seasonal energy rating Cooling
Heating
SEER
SCOP
EER - COP (Cooling/heating energy label)
Sound Pressure (very low - low - med - high) Cooling dB(A)
Heating dB(A)
Sound Power (Eurovent data) dB(A)
Air flow (very low - low - med - high) Cooling m3/h
Heating m3/h
Diameter of pipes (liquid-gas) Inches
Condensate drain diameter mm
Remote control (option)
Programming
Dimensions Height mm
Width mm
Depth mm
Weight kg
2,50 (0,90-3,00)
3,50 (0,90-5,50)
A++
A+
6.20
4.30
4,20-4,00 (A/A)
30-33-37-41
30-34-38-42
57
330-390-450-510
330-390-450-510
1/4 - 3/8
16
Eco Control
7 Day / 24 Hr
235
750
400
16
3,50 (0,90-4,00)
4,80 (0,90-6,60)
A++
A+
6.50
4.30
3,70-3,81 (A/A)
30-33-37-41
30-34-38-42
57
330-390-450-510
330-390-450-510
1/4 - 3/8
16
Eco Control
7 Day / 24 Hr
235
750
400
16
5,00 (1,20-5,80)
6,00 (1,20-6,80)
A++
A+
6.20
4.00
3,52-3,82 (A/A)
29-32-35-39
29-32-35-40
53
350-540-800-1140
350-540-800-1140
1/4 - 1/2
35
Eco Control
7 Day / 24 Hr
270
900
720
35
6,00 (1,20-6,50)
7,00 (1,20-8,00)
A++
A+
6.20
4.00
3,51-3,80 (A/A)
29-32-35-39
29-32-35-40
53
350-540-800-1140
350-540-800-1140
1/4 - 1/2
35
Eco Control
7 Day / 24 Hr
270
900
720
35
7,00 (1,50-8,00)
8,00 (1,50-8,50)
A++
A+
6.10
4.00
3,32-3,64 (A/A)
29-32-35-39
29-32-35-40
53
350-540-800-1140
350-540-800-1140
1/4 - 5/8
35
Eco Control
7 Day / 24 Hr
270
900
720
35

Outdoor Units

RAC-25NPE RAC-35NPE RAC 50NPE RAC-60NPE RAC-70NPD
Power feed
Power consumption (min - max) Cooling KW
Heating KW
Sound Pressure Cooling dB(A)
Heating dB(A)
Sound Power dB(A)
Airflow Cooling m3/h
Heating m3/h
Diameter of pipes (liquid-gas) Inches
Maximum pipe length m
Maximum piping elevation (between IDU & ODU) m
Refrigerant charge / (Pre-charged length) kg (m)
Refrigerant
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight kg
220-240V, 1Ph, 50Hz
0,60 (0,25-1,29)
0,88 (0,25-1,50)
48
49
61
1920
1620
1/4 - 3/8
20
10
0,86 (20)
R32
Rotary
548
750
288
33
220-240V, 1Ph, 50Hz
0,95 (0,25-1,46)
1,26 (0,25-1,92)
48
49
61
1920
1620
1/4 - 3/8
20
10
0,86 (20)
R32
Rotary
548
750
288
33
220-240V, 1Ph, 50Hz
1.42 (0,30-2,50)
1,50 (0,30-2,65)
50
53
65
2160
2160
1/4 - 1/2
30
20
1,50 (30)
R32
DC Twin Rotary
750
850
298
50
220-230V, 1Ph, 50Hz
1,71 (0,30-2,65)
1,84 (0,30-2,65)
50
53
65
2160
2160
1/4 - 1/2
30
20
1,50 (30)
R32
DC Twin Rotary
750
850
298
50
220-230V, 1Ph, 50Hz
2,11 (0,50-2,70)
2,20 (0,50-2,80)
50
53
65
2700
2700
1/4 - 5/8
30
20
1,60 (30)
R32
Rotary
800
850
298
52